Water Cooled Heat Pump Split Unit
Features
High Energy-efficient:
 The ratio output against input is energy efficient ratio(EER)which can be more than 6,and that of traditional electric boiler is lower than 0.95.The efficiency of gas and fuel of boiler will be less than 0.6-0.8,that of coal-burning boiler is even lower, only 0.3-0.7
 Safety and Security:
The heating between water and electricity is separated, that avoided the hidden risks like flammable, explosive, electric shock, toxicities.
 Environment-Protection:
Without discharging waste water, residue, excrescent heating and gas, it will not produce any pollution to the surroundings.
 Easy to install:
The unit can be installed in the outdoor vacant lot, the roof, the balcony, and places like large-scale garage parking, storey of equipment etc. The special equipment room is needless.
 Modular Controlling function:
As per the actual equipments, one or more units can be connected to one water heater supply system, all of them are controlled by modular type. Running period and order are adjusted automatically, Water is heated up gradually for end using.
 Convenient operation:
The system is controlled by the microcomputer. It can switch on and off automatically as per the water temperature.
 Auto-defrosting:
The parameter of defrosting and control means can be setup according to climatic conditions of different area. Defrosting can actualized in a intelligent and flexible way which can make it more complete, flexible and energy-saving.
 Auto switch on/off function:
The user can set time for starting the system so that save running cost by using electricity at a low vale condition.
 Auto anti-freezing:
Auto anti-freezing function ensures the water system not to be cracked in very low ambient temperature.
 Automatic energy adjusting:
According to ambiguous controlling principle, the unit checks the load dynamically. When the unit reaches the setting temperature, it keeps the load in balance. Thus running in the summer under very high ambient temperature will not be over loaded, and in the winter under low temperature runs stable and efficiently.
 Commercial water supply:
It is especially suitable for the hotel, sauna, school, industrial sites, shower center and indoor swimming pool.
 Top quality comes from best material:
We use the would famous key components like Copeland, Sanyo, Hitachi and Mitsubishi compressor, Alco expansion valve and Danfoss valve. Every unit will be produced precisely and tested strictly before leave the factory. The quality is assured and life shelf can be more than 15 years.
Product parameters

Model SHKF(R)-26FW SHKF(R)-35FW SHKF(R)-45FW SHKF(R)-58FW SHKF(R)-72FW
Cooling Capacity(BTU/TON) 9000BTU/0.75TON 12000BTU/1TON 16000BTU/1.3TON 20000BTU/1.7TON 25000BTU/2TON
Power(V/PH/HZ) 220V/1ph/50Hz 220V/1ph/50Hz 220V/1ph/50Hz 220V/1ph/50Hz 220V/1ph/50Hz
Cooling Capacity(W) 2600 3500 4500 5800 7200
Rated power(W) 0.66 0.87 1.1 1.41 1.71
Inpt current (A) 3.1 4 5.1 6.54 7.9
Heating Capacity(W) 2920 3960 5130 6750 8130
Rated power(W) 0.68 0.88 1.14 1.5 1.8
Inpt current (A) 3.2 4.1 5.2 7 8.3
Controller Remote Remote Remote Remote Remote
Option Wired controller Option Option Option Option Option
Outer Static Pressure (Pa) 20 (30) 20 (30) 20 (30) 20 (30) 30 (50)
Water Flow (m3/h) 0.58 0.72 0.92 1.25 1.52
In/Out water balance Rate (kPa) 18 22 30 35 35
Air Cycle amount M3/h 520 715 910 1190 1480
CFM 306 421 536 700 871
Noise (in/outdoor) dB/A 38/37 39/38 40/38 41/39 43/39
Net Weight Indoor/ ourdoor(Kg) 16/34 22/37 26/43 30/48 34/50
Compressor/Type/ Quantity HITACHI/ Rotary/1 HITACHI/ Rotary/1 HITACHI/ Rotary/1 HITACHI/ Rotary/1 HITACHI/ Rotary/1
Refrigerant/charge weight(KG) R22/0.65 R22/0.84 R22/0.95 R22/1.1 R22/1.5
Connection Liquid Pipe (mm) ¢6×0.75 ¢6×0.75 ¢6×0.75 ¢6×0.75 ¢9.52×0.75
Gas pipe (mm) ¢9.52×0.75 ¢9.52×0.75 ¢12.7×0.75 ¢12.7×0.75 ¢16×1.0
Water Pipe Input/ Output (mm) R3/4 (DN20)/R3/4 (DN20)
Indoor Unit Product Dimensions 810× 475× 235 960×475×235 1100×475×235 1300×475×235 1605× 475× 235
Outdoor Product Dimensions 507× 454× 400 507× 454× 400 628×490×435 628×490×435 628×490×435

Model SHKF(R)-86FW SHKF(R)-105FW SHKF(R)-126FW SHKF(R)-146FW SHKF(R)-175FW
Cooling Capacity(BTU/TON) 30000BTU/2.5TON 36000BTU/3TON 43000BTU/3.6TON 50000BTU/4TON 60000BTU/5TON
Power(V/PH/HZ) 220V/1ph/50Hz 380V/3ph/50Hz 380V/3ph/50Hz 380V/3ph/50Hz 380V/3ph/50Hz
Cooling Capacity(W) 8600 10500 12600 14600 17500
Rated power(W) 2.04 2.51 3.02 3.47 4.18
Inpt current (A) 9.46 3.9 4.7 5.4 6.5
Heating Capacity(W) 9630 11760 14240 16640 19600
Rated power(W) 2.18 2.71 3.24 3.7 4.45
Inpt current (A) 10.1 4.2 5 5.7 6.9
Controller Remote Remote Remote Remote Remote
Option Wired controller Option Option Option Option Option
Outer Static Pressure (Pa) 30 (50) 30 (50) 30 (50) 30 (50) 80 (100)
Water Flow (m3/h) 1.85 2.25 2.66 3.12 3.65
In/Out water balance Rate (kPa) 35 35 38 38 38
Air Cycle amount M3/h 1760 2150 2570 3010 3600
CFM 1036 1265 1513 1772 2119
Noise (in/outdoor) dB/A 43/40 44/41 45/41 46/42 46/42
Net Weight Indoor/ ourdoor(Kg) 36/68 38/73 40/74 46/77 58/83
Compressor/Type/ Quantity HITACHI/ Rotary/1 Sanyo/ Scroll/1 Sanyo/ Scroll/1 Sanyo/ Scroll/1 Sanyo/ Scroll/1
Refrigerant/charge weight(KG) R22/1.8 R22/2.1 R22/2.3 R22/2.8 R22/4.1
Connection Liquid Pipe (mm) ¢9.52×0.75 ¢9.52×0.75 ¢12.7×0.75 ¢12.7×0.75 ¢12.7×0.75
Gas pipe (mm) ¢16×1.0 ¢19×1.0 ¢19×1.0 ¢19×1.0 ¢19×1.0
Water Pipe Input/ Output (mm) R1(DN25)/ R3/4 (DN20) R1-1/4(DN32)/ R3/4 (DN20)
Indoor Unit Product Dimensions 1700× 475× 235 1940× 475× 235 1940× 490× 285 1940× 490× 285 2340× 490× 285
Outdoor Product Dimensions 775×548×520 875×584×535 875×584×535 875×584×535 875×584×535

The Power Can be 50Hz or 60Hz.